000 07519cam a2200577 i 4500
999 _c95472
_d95472
005 20260507140239.0
006 m o d
007 cr |n|||||||||
008 260507s2022 sz a ob 000 0 eng d
020 _a9783030975562
_q(electronic bk.)
020 _a3030975568
_q(electronic bk.)
020 _z9783030975555
041 _aeng
050 4 _aTA658.44
082 0 0 _223
_a624.1/762
100 1 _aAzinović, Boris,
_eauthor.
245 1 0 _aAssessment of energy-efficient building details for seismic regions /
_cBoris Azinović, Vojko Kilar, David Koren.
264 1 _aCham :
_bSpringer,
_c[2022]
264 4 _c©2022
300 _a1 online resource :
_billustrations (chiefly color).
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
490 1 _aSpringer tracts in civil engineering,
_x2366-2603
504 _aIncludes bibliographical references.
505 0 _aIntro -- Preface -- Contents -- 1 Introduction -- References -- 2 Design of the Thermal Insulation Envelope of Energy-Efficient Buildings -- 2.1 ?L± Type Structural Assembly Connections -- 2.2 ?T± Type Structural Assembly Connections -- 2.3 ?+± Type Structural Assembly Connections -- References -- 3 Structural Details in Energy-Efficient Buildings -- 3.1 Foundations on the Thermal Insulation Layer -- 3.1.1 Possible Solutions for Foundations on Thermal Insulation -- 3.1.2 Specifics of Designing Thermally Insulated Foundation Slabs in Non-earthquake-Prone Areas -- 3.1.3 Influence of the Flexible Layer of Thermal Insulation on the Seismic Response of a Building -- 3.2 Base Insulation Blocks for Preventing Thermal Bridges in Walls in Contact with Cold Elements -- 3.2.1 Types of Base Insulation Blocks -- 3.2.2 Influence of Base Insulation Blocks on Better Environmental and Energy-Efficiency Parameters -- 3.2.3 Base Insulation Blocks as Parts of Masonry Structures for Bearing Vertical Static Loads -- 3.3 Details for Preventing Thermal Bridges in Cantilever Structures -- 3.3.1 Precast Element Solutions for Thermal Bridges in Cantilever Structures -- 3.3.2 Comparison of the Environmental and Energy-Efficiency Parameters of an Insulated and Uninsulated Reinforced Concrete Cantilever Slab -- 3.3.3 Selection Principles of Precast Load-Bearing Thermal Insulation Elements Subject to Vertical Static Loads -- 3.4 Building Connection Detail Between the Roof and Outer Wall -- 3.4.1 Environmental and Energy-Efficiency Aspects of the Building Connection Detail Between the Roof and an Outer Wall -- References -- 4 Evaluation of Critical Structural Assemblies -- 4.1 Detail Evaluation Methodology for Energy-Efficient Buildings -- 4.1.1 Importance of Environmental and Energy-Efficiency Parameters -- 4.1.2 Importance of Technical and Structural Parameters.
505 8 _a4.1.3 Importance of External Parameters -- 4.2 Environmental and Energy-Efficiency Parameters -- 4.2.1 Thermal Transmittance of Structural Assemblies (E1) -- 4.2.2 Continuity of Thermal Insulation (E2) -- 4.2.3 Condensation and Thermal Comfort (E3) -- 4.2.4 Influence on the Use of Energy (E4) -- 4.2.5 Airtightness (E5) -- 4.2.6 Life Cycle Assessment (E6) -- 4.2.7 Durability and Sustainability (E7) -- 4.3 Technical and Structural Parameters -- 4.3.1 Load-Bearing Capacity (K1) -- 4.3.2 Minimum Dimensions and Stiffness (K2) -- 4.3.3 Symmetry (K3) -- 4.3.4 Continuity or Uniformity of the Load-Bearing Structure (K4) -- 4.3.5 Eccentricity or a Shift in the Structure According to the Primary Load-Bearing Axis (K5) -- 4.3.6 Capacity Design Method (K6) -- 4.3.7 Connections of Primary and Secondary (Non-)Load-Bearing Elements (K7) -- 4.4 External Parameters -- 4.4.1 Location (Z1) -- 4.4.2 Importance of a Building (Z2) -- 4.4.3 Influence on the Global Analysis (Z3) -- 4.4.4 Complexity of Construction (Z4) -- 4.4.5 Penetrations and Openings (Z5) -- 4.4.6 Economic Aspect (Z6) -- 4.5 Assessment Based on Evaluation Parameters, Weighting Factors and External Parameters -- 4.6 Presentation of the Results -- References -- 5 Case Study: Using Methodology to Assess the Selected Details -- 5.1 Building Connection Detail Between an Outer Wall and the Foundation Slab -- 5.2 Building Connection Detail Between the Load-Bearing Balcony Structure and an Outer Wall -- 5.3 Building Connection Detail Between an Outer Wall and the Unheated Basement -- 5.4 Building Connection Detail Between an Outer Wall and the Roof -- References -- 6 Conclusions -- References -- Appendix Examples of the Use of the Methodology for Evaluating Structural Details.
520 _aThis open access book presents a methodology for the assessment of structural building details, taking into account the contemporary guidelines for earthquake-resistant and energy-efficient buildings. A review of structural details for energy-efficient buildings revealed that in some cases the structural system is interrupted, leading to solutions which are not suitable for earthquake-prone regions. Such typical examples would be the use of thermal insulation under the building foundation and reduction of the load-bearing elements' dimensions - also at the potential locations of plastic hinges which are crucial for the dissipation of seismic energy. The proposed methodology of assessment favours a collaboration of architects, engineers, contractors and investors in the early stage of building design. By this the methodology enables efficient decision-making and contributes to a selection of optimal building structural details. The book starts by presenting the typical structural details of the thermal envelope of energy-efficient buildings together with the scientific background required for understanding the process of detail development from all the relevant aspects. Over 20 examples of most frequent details are described and analysed to raise awareness of the importance of earthquake resistance, sustainability, energy-efficiency and thermal comfort for users.
650 0 _aBuildings
_xEarthquake effects.
_0http://id.loc.gov/authorities/subjects/sh85017774
650 0 _aEarthquake resistant design.
_0http://id.loc.gov/authorities/subjects/sh85040493
650 0 _aArchitecture and energy conservation.
_0http://id.loc.gov/authorities/subjects/sh85006885
650 0 _aSustainable buildings.
_0http://id.loc.gov/authorities/subjects/sh2003001382
650 6 _aConstructions
_xEffets des tremblements de terre sur.
650 6 _aConception parasismique.
650 6 _aArchitecture et économies d'énergie.
650 6 _aConstructions durables.
650 7 _aseismic design.
_2aat
650 7 _aenergy efficient buildings.
_2aat
650 7 _aArchitecture and energy conservation
_2fast
650 7 _aBuildings
_xEarthquake effects
_2fast
650 7 _aEarthquake resistant design
_2fast
650 7 _aSustainable buildings
_2fast
655 4 _aElectronic books.
700 1 _aKilar, Vojko,
_eauthor.
_1https://id.oclc.org/worldcat/entity/E39PCjJf6rBQFDv4g4CQvvfg8C
_0http://id.loc.gov/authorities/names/n2021030373
700 1 _aKoren, David,
_eauthor.
830 0 _aSpringer tracts in civil engineering.
_x2366-2603
_0http://id.loc.gov/authorities/names/no2017088242
856 4 0 _uhttps://directory.doabooks.org/handle/20.500.12854/81689
_yFull text is available at the Directory of Open Access Books. Click here to view.
856 4 0 _uhttps://link.springer.com/book/10.1007/978-3-030-97556-2
_ySpringer Nature
942 _2ddc
_cOA