Three-phase electrical power / (Record no. 50982)

000 -LEADER
fixed length control field 03509cam a2200361 i 4500
001 - CONTROL NUMBER
control field 18598522
003 - CONTROL NUMBER IDENTIFIER
control field CITU
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250425110012.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150430s2016 flua b 001 0 eng
010 ## - LIBRARY OF CONGRESS CONTROL NUMBER
LC control number 2015016379
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9781498737777
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title eng
042 ## - AUTHENTICATION CODE
Authentication code pcc
050 00 - LIBRARY OF CONGRESS CALL NUMBER
Classification number TK1165
Item number .F54 2016
082 00 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 621.319/13
Edition number 23
100 1# - MAIN ENTRY--PERSONAL NAME
Preferred name for the person Fleckenstein, Joseph E.,
Relator term author.
245 10 - TITLE STATEMENT
Title Three-phase electrical power /
Statement of responsibility, etc Joseph E. Fleckenstein.
264 #1 - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc Boca Raton :
Name of publisher, distributor, etc CRC Press,
Date of publication, distribution, etc [2016]
264 #4 - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc c2016
300 ## - PHYSICAL DESCRIPTION
Extent xvii, 413 pages :
Other physical details illustrations ;
Dimensions 24 cm
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Media type code n
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Carrier type code nc
Source rdacarrier
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes bibliographical references (pages 401-402) and index.
505 ## - CONTENTS
Formatted contents note Alternating CurrentSingle-Phase Alternating CurrentThree-Phase Alternating Current: Basic ConceptsAC Impedance and AdmittanceProblemsGeneration, Transmission, and DistributionGenerationTransmissionDistributionElectrical GearPer Unit CalculationsCybersecurityProblemsGroundingDefinitionsReasons for GroundingSingle-Phase GroundingThree-Phase GroundingProblemsCalculating Currents in Three-Phase CircuitsCalculating Currents in Balanced Three-Phase CircuitsCalculating Currents in Unbalanced Three-Phase Circuits: GeneralCombined Balanced or Unbalanced Three-Phase CircuitsProblemsCalculating Three-Phase PowerUnitsCalculating Power of a Single-Phase CircuitCalculating Power in Balanced Three-Phase CircuitsCalculating Power in Unbalanced Three-Phase CircuitsCalculating Power in a Three-Phase Circuit with Mixed Wye and Delta LoadsNonlinear Electrical CircuitsConclusionProblemsDemand and Demand ResponseDemand DefinedDemand ResponseSmart GridProblemsInstruments and MetersPower MeasurementsMeasuring Power in Three-Phase, Three-Wire CircuitsMeasuring Power in a Three-Phase, Four-Wire CircuitPower Analyzers and Power Quality MetersWatt-Hour MetersDemand MetersSmart MetersSubmetersPhase Sequence MetersEarth ResistanceMegohmmeterHigh-Potential TesterMultimetersProblemsCircuit ProtectionGeneral RequirementsUngrounded SystemsOvercurrentFaultsCircuit BreakersFusesShort Circuit StudyDamage CurvesProblemsMotors and Motor ProtectionMotor DesignsMotor ControlsProblemsPower Factor CorrectionLow Power Factor PenaltiesLow Power Factor CausesCapacitors for Power Factor CorrectionCapacitors DefinedCapacitor LocationsHarmonic MitigationSpecial ConsiderationsSizing CapacitorsProblemsTariffsResidential TariffsCommercial and Industrial TariffsSummary of Common Electric TariffsProblemsRelays and ContactorsRelays and Contactors: GeneralElectromechanical Control RelaysSolid-State RelaysReed RelaysEnvironmental RequirementsEnclosuresProtection RelaysContactorsTerminals and TerminationsCertificationsCommon Relay-Associated MistakesProblemsElectrical DrawingsOne-Line DiagramsThree-Line DiagramsLogic DiagramsLadder DiagramsPanel Layout DrawingsCable DrawingsRacewayConnection DrawingsProblemsAppendixSymbols, Acronyms, and EquationsReferences
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Electric currents, Alternating
General subdivision Three-phase.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Electric power distribution
General subdivision Multiphase.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Electric power transmission
General subdivision Alternating current.
906 ## - LOCAL DATA ELEMENT F, LDF (RLIN)
a 7
b cbc
c orignew
d 1
e ecip
f 20
g y-gencatlg
942 ## - ADDED ENTRY ELEMENTS
Source of classification or shelving scheme
Item type BOOK
Issues (borrowed), all copies 4
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Source of acquisition Cost, normal purchase price Inventory number Total Checkouts Full call number Barcode Date last seen Date checked out Price effective from Item type
          COLLEGE LIBRARY COLLEGE LIBRARY SUBJECT REFERENCE 2017-09-04   13995.00 47949 4 621.31913 F622 2016 CITU-CL-47949 2025-05-06 2025-04-25 2020-10-19 BOOK